Phone number: (315) 930-4535
Email: sales@buyitsolutions.com
Address: 241-40 86th Rd Jamaica New York 11426 United States
EIN NUMBER: 93-2319428
D-U-N-S Number: 130972525
Skip to product information
Black Box
Black Box IC821A serial converter/repeater/isolator RS-232 RS-422/485
SKU:
IC821A
Condition: New
$182.24 USD
Pickup currently not available
✔
Factory-Sealed
Sourced from authorized distributors
✔
Manufacturer Warranty
Terms set by the brand
✔
Enterprise Expertise
Business Procurement
Free standard shipping over $2,500
Delivery estimates are based on product availability, destination, fulfillment method, and qualifying order requirements. 30-day returns; 20% restocking fee on non-defective returns. Shipping policy · Return policy
Loading documents...
Need Help Before You Order?
Check compatibility, availability, or volume pricing with an IT procurement specialist.
Enterprise IT Procurement Built for Business
Source servers, networking, storage, workstations, and business technology through established distribution channels with dedicated procurement support.
1,700+
Business Accounts Supported
32,000+
Enterprise Hardware Products Available
Fast, Reliable Procurement Support
Reach out for responsive product availability, part numbers, pricing, and additional hardware needs.
4–8 Hrs
Typical RFQ Response Target
Multi-Vendor
Hardware Sourcing
Keep Your IT Projects Moving
For business hardware purchases and larger deployments, get shipment information, order coordination, and delivery support.
Manufacturer Warranty Coverage
Eligible products include warranty coverage provided by the original manufacturer according to applicable brand and product terms.
Brand Warranty TermsFactory-Sealed HardwareOEM Support Eligibility
A Trusted Source for Enterprise Hardware
Source factory-sealed IT hardware through established technology distribution channels, with support for individual purchases, BOM requests, and larger business requirements.
112+
Technology Brands
32,000+
Hardware Products Available
Key Features
Universal RS-232 to RS-422/485 Converter with optional Opto-Isolation
- Convert RS-232 to 4-wire RS-422 or to 2- or 4-wire RS-485.
- Features 2000-VAC isolation.
- RoHS compliant.
- Selectable RS-422 operation.
- Select RS-485 for 2-wire half-duplex or 4-wire full-duplex.
- Auto RS-485 driver control.
Further Details
The BLACK BOX® Universal RS-232 to RS-422/485 Converter with Opto-Isolation isolates and converts RS-232 signals into RS-422/RS-485 signals and vice versa. Unlike other converters, external software is not required to control data flow. The RS-232 input is wired for DCE through a DB9 female connector, and RS-422/RS-485 signals are interfaced through a removable terminal block. To supply external power to the terminal block, you need our 120-VAC/12-VDC Wallmount Power Supply (PS1003).
For RS-232, the connection requires RD, TD, and Signal Ground.
In RS-422 mode, the driver is always enabled for full-duplex communications. A twisted pair is required for transmit, and a twisted pair is also required for receive. A ground reference wire is also needed. Switch settings are Switch 1: RS-422; Switch 2: Echo On; Switches 3 and 4: 4 Wire.
In both RS-485 modes, the RS-485 driver is automatically enabled during each space state by the presence of an RS-232 signal. When the RS-232 data is in a mark or idle state, the RS-485 driver is disabled and the RS-485 data lines are held in a mark state by the bias provided by a 4.7-ohm resistor; the value of this resistor may need to be changed, depending on the termination you use.
To connect to several RS-485 devices with minimal wire, select the unit's 2-wire, half-duplex RS-485 mode. When data is requested, the addressed device transmits and then reverts back to receive status. Switch settings for this mode are Switch 1: RS-485; Switch 2: Echo Off; Switches 3 and 4: 2 Wire.
For 4-wire master/slave circuits, select the unit's 4-wire, full-duplex RS-485 mode. In this mode, addressed devices can receive data while transmitting data from a previous request. When used as a master in a single-master system, Switch 1 may be selected because the unit is the only transmitter in the system. When used as an RS-485 slave, the RS-232 device must provide addressability. Biasing in a master/slave system is provided by the end-of-line slave. Switch settings for this mode are Switch 1: RS-485; Switch 2: Echo On; Switches 3 and 4: 4 Wire.
NOTE: Power Supply (PS1003) is not included, but is required.
Key Features
- Convert RS-232 to 4-wire RS-422 or to 2- or 4-wire RS-485.
- Enable you to select RS-485 2-wire half-duplex or RS-485 4-wire full-duplex operation.
- Selectable RS-422 operation with transmit and receive always enabled.
- Automatic RS-485 driver control, so it works without any special programming for handshaking signals.
- No external power is required if two RS-232 output handshake lines are available.
- Universal RS-232 to RS-422/485 Converter
- Bidirectional data conversion.
- Enables transmitter from RS-232 TD signal and receiver when not transmitting.
- Set operating mode with four switches.
- Converts using either port power or power from an external 12VDC power supply (not included).
Description
Quick Facts- Convert RS-232 to 4-wire RS-422 or to 2- or 4-wire RS-485.
- Features 2000-VAC isolation.
- RoHS compliant.
- Selectable RS-422 operation.
- Select RS-485 for 2-wire half-duplex or 4-wire full-duplex.
- Auto RS-485 driver control.
Further Details
The BLACK BOX® Universal RS-232 to RS-422/485 Converter with Opto-Isolation isolates and converts RS-232 signals into RS-422/RS-485 signals and vice versa. Unlike other converters, external software is not required to control data flow. The RS-232 input is wired for DCE through a DB9 female connector, and RS-422/RS-485 signals are interfaced through a removable terminal block. To supply external power to the terminal block, you need our 120-VAC/12-VDC Wallmount Power Supply (PS1003).
For RS-232, the connection requires RD, TD, and Signal Ground.
In RS-422 mode, the driver is always enabled for full-duplex communications. A twisted pair is required for transmit, and a twisted pair is also required for receive. A ground reference wire is also needed. Switch settings are Switch 1: RS-422; Switch 2: Echo On; Switches 3 and 4: 4 Wire.
In both RS-485 modes, the RS-485 driver is automatically enabled during each space state by the presence of an RS-232 signal. When the RS-232 data is in a mark or idle state, the RS-485 driver is disabled and the RS-485 data lines are held in a mark state by the bias provided by a 4.7-ohm resistor; the value of this resistor may need to be changed, depending on the termination you use.
To connect to several RS-485 devices with minimal wire, select the unit's 2-wire, half-duplex RS-485 mode. When data is requested, the addressed device transmits and then reverts back to receive status. Switch settings for this mode are Switch 1: RS-485; Switch 2: Echo Off; Switches 3 and 4: 2 Wire.
For 4-wire master/slave circuits, select the unit's 4-wire, full-duplex RS-485 mode. In this mode, addressed devices can receive data while transmitting data from a previous request. When used as a master in a single-master system, Switch 1 may be selected because the unit is the only transmitter in the system. When used as an RS-485 slave, the RS-232 device must provide addressability. Biasing in a master/slave system is provided by the end-of-line slave. Switch settings for this mode are Switch 1: RS-485; Switch 2: Echo On; Switches 3 and 4: 4 Wire.
NOTE: Power Supply (PS1003) is not included, but is required.
Specifications
| Technical details | |
|---|---|
| Serial ports quantity | 2 |
| Output interface | RS-422/485 |
| Host interface | RS-232 |
| Weight & dimensions | |
| Dimensions (WxDxH) | 0.906 x 3.9 x 1.69" (23 x 99 x 43 mm) |
| Power | |
| Input voltage | 10 - 48 V |
| Input current | 0.028 A |
Product Specs
Universal RS-232 to RS-422/485 Converter with optional Opto-Isolation
- Convert RS-232 to 4-wire RS-422 or to 2- or 4-wire RS-485.
- Features 2000-VAC isolation.
- RoHS compliant.
- Selectable RS-422 operation.
- Select RS-485 for 2-wire half-duplex or 4-wire full-duplex.
- Auto RS-485 driver control.
Further Details
The BLACK BOX® Universal RS-232 to RS-422/485 Converter with Opto-Isolation isolates and converts RS-232 signals into RS-422/RS-485 signals and vice versa. Unlike other converters, external software is not required to control data flow. The RS-232 input is wired for DCE through a DB9 female connector, and RS-422/RS-485 signals are interfaced through a removable terminal block. To supply external power to the terminal block, you need our 120-VAC/12-VDC Wallmount Power Supply (PS1003).
For RS-232, the connection requires RD, TD, and Signal Ground.
In RS-422 mode, the driver is always enabled for full-duplex communications. A twisted pair is required for transmit, and a twisted pair is also required for receive. A ground reference wire is also needed. Switch settings are Switch 1: RS-422; Switch 2: Echo On; Switches 3 and 4: 4 Wire.
In both RS-485 modes, the RS-485 driver is automatically enabled during each space state by the presence of an RS-232 signal. When the RS-232 data is in a mark or idle state, the RS-485 driver is disabled and the RS-485 data lines are held in a mark state by the bias provided by a 4.7-ohm resistor; the value of this resistor may need to be changed, depending on the termination you use.
To connect to several RS-485 devices with minimal wire, select the unit's 2-wire, half-duplex RS-485 mode. When data is requested, the addressed device transmits and then reverts back to receive status. Switch settings for this mode are Switch 1: RS-485; Switch 2: Echo Off; Switches 3 and 4: 2 Wire.
For 4-wire master/slave circuits, select the unit's 4-wire, full-duplex RS-485 mode. In this mode, addressed devices can receive data while transmitting data from a previous request. When used as a master in a single-master system, Switch 1 may be selected because the unit is the only transmitter in the system. When used as an RS-485 slave, the RS-232 device must provide addressability. Biasing in a master/slave system is provided by the end-of-line slave. Switch settings for this mode are Switch 1: RS-485; Switch 2: Echo On; Switches 3 and 4: 4 Wire.
NOTE: Power Supply (PS1003) is not included, but is required.
Key Features
- Convert RS-232 to 4-wire RS-422 or to 2- or 4-wire RS-485.
- Enable you to select RS-485 2-wire half-duplex or RS-485 4-wire full-duplex operation.
- Selectable RS-422 operation with transmit and receive always enabled.
- Automatic RS-485 driver control, so it works without any special programming for handshaking signals.
- No external power is required if two RS-232 output handshake lines are available.
- Universal RS-232 to RS-422/485 Converter
- Bidirectional data conversion.
- Enables transmitter from RS-232 TD signal and receiver when not transmitting.
- Set operating mode with four switches.
- Converts using either port power or power from an external 12VDC power supply (not included).
Description
Quick Facts- Convert RS-232 to 4-wire RS-422 or to 2- or 4-wire RS-485.
- Features 2000-VAC isolation.
- RoHS compliant.
- Selectable RS-422 operation.
- Select RS-485 for 2-wire half-duplex or 4-wire full-duplex.
- Auto RS-485 driver control.
Further Details
The BLACK BOX® Universal RS-232 to RS-422/485 Converter with Opto-Isolation isolates and converts RS-232 signals into RS-422/RS-485 signals and vice versa. Unlike other converters, external software is not required to control data flow. The RS-232 input is wired for DCE through a DB9 female connector, and RS-422/RS-485 signals are interfaced through a removable terminal block. To supply external power to the terminal block, you need our 120-VAC/12-VDC Wallmount Power Supply (PS1003).
For RS-232, the connection requires RD, TD, and Signal Ground.
In RS-422 mode, the driver is always enabled for full-duplex communications. A twisted pair is required for transmit, and a twisted pair is also required for receive. A ground reference wire is also needed. Switch settings are Switch 1: RS-422; Switch 2: Echo On; Switches 3 and 4: 4 Wire.
In both RS-485 modes, the RS-485 driver is automatically enabled during each space state by the presence of an RS-232 signal. When the RS-232 data is in a mark or idle state, the RS-485 driver is disabled and the RS-485 data lines are held in a mark state by the bias provided by a 4.7-ohm resistor; the value of this resistor may need to be changed, depending on the termination you use.
To connect to several RS-485 devices with minimal wire, select the unit's 2-wire, half-duplex RS-485 mode. When data is requested, the addressed device transmits and then reverts back to receive status. Switch settings for this mode are Switch 1: RS-485; Switch 2: Echo Off; Switches 3 and 4: 2 Wire.
For 4-wire master/slave circuits, select the unit's 4-wire, full-duplex RS-485 mode. In this mode, addressed devices can receive data while transmitting data from a previous request. When used as a master in a single-master system, Switch 1 may be selected because the unit is the only transmitter in the system. When used as an RS-485 slave, the RS-232 device must provide addressability. Biasing in a master/slave system is provided by the end-of-line slave. Switch settings for this mode are Switch 1: RS-485; Switch 2: Echo On; Switches 3 and 4: 4 Wire.
NOTE: Power Supply (PS1003) is not included, but is required.
Specifications
| Technical details | |
|---|---|
| Serial ports quantity | 2 |
| Output interface | RS-422/485 |
| Host interface | RS-232 |
| Weight & dimensions | |
| Dimensions (WxDxH) | 0.906 x 3.9 x 1.69" (23 x 99 x 43 mm) |
| Power | |
| Input voltage | 10 - 48 V |
| Input current | 0.028 A |
Loading product information from Icecat...
Related products
FAQ
Questions? We're Here to Help.
Can't find what you're looking for? Our team is available through live chat.
Need immediate assistance?
Our sales engineering and accounts team is available Monday through Friday, 9:00 AM to 6:00 PM ET.
Call (315) 930-4535We offer computing hardware, networking equipment, servers and storage, plus power and security products from leading technology brands.
Yes, our team provides pre-sale consultation and post-purchase support to ensure you get the right solutions for your needs.
Return new, undamaged items with all accessories and original packaging within 30 days of delivery. A 20% restocking fee applies to non-defective returns. Defective, damaged or incorrect items are replaced or refunded, with a free return label.
Standard shipping is $25, free on orders over $2,500 in the contiguous US Express is $40, or $350 on orders over $2,500. Alaska and Hawaii ship by air for $85. In-stock orders leave the warehouse within 2-3 business days, standard transit is 5-7 business days and express 1–2 days.
Absolutely! Contact our sales team via live chat, phone, or email to discuss your requirements and receive a customized quote.
Popular Queries
LG 50UL3Q-E signage display Digital signage flat panel 50" LED Wi-Fi 350 cd/m² 4K Ultra HD Black WebOS 16/7
DELL Pro 65 Plus P6524QT Interactive flat panel 64.53" LCD 350 cd/m² 4K Ultra HD Black Touchscreen
Logitech Tap Scheduler 2 video conferencing system Ethernet LAN Video conferencing service management system
HP Poly Savi 7310-M Office Microsoft Teams Certified DECT 1920-1930 MHz Headset TAA
Juniper EX4100-24T network switch Unmanaged Power over Ethernet (PoE) 1U Gray
HP Poly CCX 600 Business Media Phone with Open SIP with Power Supply
NETGEAR GSM4352PB Managed L2/L3/L4 Gigabit Ethernet (10/100/1000) Power over Ethernet (PoE) 1U Black
HPE Aruba Networking CX 6200F 24G Class-4 PoE 4SFP+ 370W Managed L3 Gigabit Ethernet (10/100/1000) Power over Ethernet (PoE) 1U
Ubiquiti USW-Pro-Max-24-PoE L3 2.5G Ethernet (100/1000/2500) Power over Ethernet (PoE) Gray
HP Poly Trio C60 IP Conference Phone Full Radio and PoE-enabled GSA/TAA
HP Poly Trio C60 IP Conference Phone for Microsoft Teams and PoE-enabled No Radio GSA/TAA
AddOn Networks QSFP28-100GB-SR4-E-AR-AO network transceiver module Fiber optic 100000 Mbit/s 850 nm
Axiom Q28-100G-BIDI-DLN-AX network transceiver module Fiber optic 100000 Mbit/s QSFP28
HP Poly CCX 400 Business Media Phone for Microsoft Teams and PoE-enabled
HP Poly TC10 White Touch Controller
View all →