Skip to product information
CyberPower M550L uninterruptible power supply (UPS) Line-Interactive 0.55 kVA 440 W 4 AC outlet(s)
Cyberpower

CyberPower M550L uninterruptible power supply (UPS) Line-Interactive 0.55 kVA 440 W 4 AC outlet(s)

Part number: M550L
Sale price  $480.32 Regular price  $594.95
Save $114.63
19% OFF

Shipping time varies based your on location.

Enjoy Free Shipping on orders over $2000 USD

M550L, 550 VA, 440 W, 120 V, 60 Hz, 5-15R-HG, 12 V, 7 Ah

Key Features

  • Tested to UL-60601-1 for use in patient-care settings
  • Ideal for diagnostic imaging, medical devices, nurses stations and lab equipment
  • Reduces current leakage to under 100μA (microamps)
  • Includes a hospital-grade NEMA 5-15P plug and 4 hospital-grade NEMA 5-15R outlets
  • Sealed LCD screen resists dirt, debris and spray
  • Hot-swappable and replaceable batteries eliminate unnecessary downtime

Description

The CyberPower M550L medical-grade UPS delivers clean, consistent backup power to sensitive medical equipment in hospitals and healthcare facilities. Designed for use in patient care vicinities, the M550L has been tested to meet all UL 60601-1 requirements, and includes hospital-grade plugs and outlets. The M550L also includes a built-in isolation transformer to minimize the current leakage and eliminate line noise, a tip-resistant mini-tower design, replaceable batteries, and a sealed, spray-resistant LCD panel.

The M550L medical-grade UPS is covered by a three-year warranty (including coverage of batteries) and a $400,000 Connected Equipment Guarantee.

NOTE: This UPS is not intended for use in critical care or life support applications.

Battery Backup
Provides power to cover shorter-outages and supplies power long enough for equipment to properly shut down when utility power fails for longer periods of time. Helps prevent loss of data and minimizes the component stress caused by a hard shutdown.

Surge Protection
Diverts excess voltage away from sensitive electronic equipment during an AC power surge or power spike to prevent damage.

Line Interactive Topology
Exists when a UPS has an autotransformer that regulates low voltages (e.g., brownouts) and over voltages (e.g., spikes) without having to switch to battery.

Automatic Voltage Regulation (AVR)
Provides clean, consistent AC power by automatically regulating low voltages and over voltages, within defined tolerances, when incoming utility power has minor fluctuations.

UL 60601-1 Tested
Meets all UL 60601-1 requirements necessary for use in patient-care environments.

Hospital-Grade Plugs & Outlets
Offer an added degree of safety and reliability to the input/output connections of hospital-grade equipment.

Isolation Transformer
Minimizes the current leakage and cumulative shock potential of connected equipment to below 100μA (microamps) and helps to alleviate line noise.

Sealed LCD Screen
Resists dirt, debris and spray, and can withstand repeated cleaning procedures common to patient-care environments.

Multifunction LCD Panel
Displays immediate, detailed information on the UPS battery and power conditions, alerting users to potential problems before they can affect critical equipment and cause downtime.

Ultra Quiet Design
Minimizes noise during operation for a quieter patient environment.

Replaceable Batteries
Can be quickly accessed and replaced by a qualified technician. Batteries are hot-swappable to eliminate unnecessary downtime.

PowerPanel® Business Edition Software
Provides a user-friendly dashboard interface for controlling and monitoring the UPS. Free software download available. See the Resources tab.

Three-Year Warranty
CyberPower will repair or replace a defective UPS system (including batteries) within three years of the purchase date. See warranty for details.

Connected Equipment Guarantee
CyberPower will repair or replace properly connected equipment if it is damaged by a power surge.

Specifications

Power
Output frequency 60 Hz
Output power factor 0.8
Output power 440 W
Input operation voltage (min) 88 V
Input operation voltage (max) 150 V
Output operation voltage (min) 120 V
Output operation voltage (max) 120 V
Surge energy rating 1445 J
Maximum current 10 A
Output power capacity 0.55 kVA
Input frequency 60 Hz
Ports & interfaces
Cable length 70.9" (1.8 m)
Socket circuit breaker Yes
USB port Yes
Serial interface Yes
Serial interface type RS-232
AC outlets quantity 4 AC outlet(s)
AC outlet types NEMA 5-15R
Power plug NEMA 5-15P-HG
USB 2.0 ports quantity 1
RS-232 ports 1
USB port type USB Type-B
Performance
Audible alarm modes Alarm when on battery, Fault, Low battery alarm, Overload alarm
UPS topology Line-Interactive
Waveform Pseudo sine
Automatic Voltage Regulation (AVR) Yes
EMI/RFI noise filtering Yes
Power protection features Overload
Audible alarm(s) Yes
Transfer time (Line Mode to Battery Mode) 10 ms
Features
Output frequency 60 Hz
Audible alarm modes Alarm when on battery, Fault, Low battery alarm, Overload alarm
UPS topology Line-Interactive
Waveform Pseudo sine
Automatic Voltage Regulation (AVR) Yes
Output power factor 0.8
Output power 440 W
Input operation voltage (min) 88 V
Input operation voltage (max) 150 V
Output operation voltage (min) 120 V
Output operation voltage (max) 120 V
Surge energy rating 1445 J
Maximum current 10 A
EMI/RFI noise filtering Yes
Power protection features Overload
Audible alarm(s) Yes
Output power capacity 0.55 kVA
Socket circuit breaker Yes
Transfer time (Line Mode to Battery Mode) 10 ms
Input frequency 60 Hz
Battery
Number of batteries supported 2
Battery voltage 12 V
Battery capacity 7 Ah
Battery technology Sealed Lead Acid (VRLA)
Typical backup time at half load 25 min
Typical backup time at full load 8 min
Hot-swap battery Yes
Battery recharge time(90%) 8 h
Design
Form factor Mini Tower
Product colour White
Safety UL1778, CSA, FCC 15 A (EMI), UL60601-1
Cable length 70.9" (1.8 m)
Display type LCD
Operational conditions
Operating temperature (T-T) 0 - 40 °C
Storage temperature (T-T) -15 - 45 °C
Operating relative humidity (H-H) 0 - 95%
Operating altitude 0 - 118110.2" (0 - 3000 m)
Technical details
Output frequency 60 Hz
Compliance certificates RoHS
Weight & dimensions
Weight 30.2 lbs (13.7 kg)
Width 6.38" (162 mm)
Height 5.39" (137 mm)
Depth 13.7" (347 mm)
Packaging data
Manual Yes
Cables included Serial, USB cable
Certificates
Safety UL1778, CSA, FCC 15 A (EMI), UL60601-1
Packaging content
Manual Yes
Cables included Serial, USB cable

You may also like