Skip to product information
Tripp Lite SUINT1000LCD2U uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA 900 W 6 AC outlet(s)
Tripp Lite

Tripp Lite SUINT1000LCD2U uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA 900 W 6 AC outlet(s)

Part number: SUINT1000LCD2U
Sale price  $1,065.46 Regular price  $2,237.34
Save $1,171.88
52% OFF

Shipping time varies based your on location.

Enjoy Free Shipping on orders over $2000 USD

SmartOnline 1000VA 900W 208/230V Double-Conversion UPS - 8 Outlets, Extended Run, Network Card Option, LCD, USB, DB9, 2U Rack/Tower

Key Features

  • Updated design for 2025
  • Protects equipment against blackouts, brownouts, transient surges and line noise
  • Keeps equipment running during outages to allow time for file saves and safe shutdown
  • Zero transfer time between on-line and battery modes for uninterrupted operation
  • ENERGY STAR 2.0-certified to save electricity, lower costs and protect the environment
  • Menu-driven LCD keeps you up to date with status info and other vital analytics
  • Compatible with Eaton Tripp Lite power cords to simplify deployment and enhance reliability

Description

Double-Conversion UPS Protects Equipment Against Damage, Downtime and Data Loss
This on-line double-conversion UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC. Constant on-line operation completely isolates sensitive equipment from every power problem on the AC line. The SmartOnline® SUINT1000LCD2U provides the highest level of power protection and battery backup for education, healthcare, military, government and other mission-critical IT applications where space is limited, but premium power reliability is essential.

Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Zero transfer time between on-line and battery modes maintains continuous operation of connected equipment without interruption or rebooting. Extra runtime is available by connecting up to four optional extended battery modules (BP48RT, sold separately).

Optional LX Platform Network Management Card Allows Remote Access 24/7
The WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.

C13 Outlets Protect Your Connected Components
Eight C13 outlets provide connected equipment with pure sine wave AC output and allow you to manage power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Four outlets are grouped into two load banks that let you shed non-critical loads to extend runtime for critical loads.

Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.

ENERGY STAR-Certified to Help You Save Money and Protect the Environment
By meeting strict U.S. Department of Energy and U.S. Environmental Protection Agency requirements, this ENERGY STAR 2.0 UPS system provides high operational efficiency to signal a reduction in BTU emissions, save on utility and cooling costs and help protect the environment.

Clear LCD Interface Keeps You Informed at a Glance
The menu-driven front-panel LCD provides detailed alarms and notifications to help diagnose any issues. It provides system status, event logs, battery and power module status, usage analytics, serial number, firmware update info and more. Audible alarms can be disabled through the front menu when the UPS goes to battery power. The LCD rotates to accommodate both rack-mount and tower installation.

Advanced Communications Ports Allow for Automatic Saves and Shutdowns
RS-232 and USB ports connect to a device for a variety of communication options (cables are included). A dry-contact relay port can be programmed through the LCD to provide reliable communications to automation and industrial components. The RPO/ROO port permits emergency shutdown or remote restart of all connected equipment.

Versatile Installation Options
You can mount the SUINT1000LCD2U in just 2U of space in an EIA-standard 19-inch rack using the included hardware. You can also adapt it for tower installation using the included support stands. The C14 power inlet accepts a variety of user-supplied input cords.

Specifications

Power
Output voltage regulation 2%
Output power 900 W
Input operation voltage (min) 200 V
Input operation voltage (max) 240 V
Output operation voltage (min) 200 V
Output operation voltage (max) 240 V
Surge energy rating 627 J
Maximum current 4.99 A
Efficiency 93%
Output power capacity 1 kVA
Input frequency 50/60 Hz
Performance
Audible alarm modes Fault, Low battery alarm, Overload alarm
UPS topology Double-conversion (Online)
Waveform Sine
Number of input phases 1
LED indicators Yes
EMI/RFI noise filtering Yes
Surge protection Yes
Power protection features Over voltage, Under voltage
Noise level 45 dB
Audible alarm(s) Yes
Features
Country of origin China
Audible alarm modes Fault, Low battery alarm, Overload alarm
UPS topology Double-conversion (Online)
Waveform Sine
Output voltage regulation 2%
Number of input phases 1
Output power 900 W
Input operation voltage (min) 200 V
Input operation voltage (max) 240 V
Output operation voltage (min) 200 V
Output operation voltage (max) 240 V
Surge energy rating 627 J
Maximum current 4.99 A
Efficiency 93%
EMI/RFI noise filtering Yes
Surge protection Yes
Power protection features Over voltage, Under voltage
Noise level 45 dB
Audible alarm(s) Yes
Output power capacity 1 kVA
Input frequency 50/60 Hz
Ports & interfaces
AC outlets quantity 6 AC outlet(s)
AC outlet types C13 coupler, C14 coupler
Battery
Typical backup time at half load 12.3 min
Typical backup time at full load 4.7 min
Hot-swap battery Yes
Cold start Yes
Design
Country of origin China
Rack capacity 2U
Form factor Rackmount
LED indicators Yes
Product colour Black
Cooling type Active
Housing material Metal
Display type LCD
Operational conditions
Operating temperature (T-T) 0 - 40 °C
Storage temperature (T-T) -15 - 50 °C
Operating relative humidity (H-H) 5 - 95%
Storage relative humidity (H-H) 5 - 95%
Technical details
Sustainability certificates ENERGY STAR
Compliance certificates RoHS
Certificates
Compliance certificates RoHS
Packaging content
Manual Yes
Cables included Input power cable, Output power cable, USB cable
Cooling
Cooling type Active
Sustainability
Sustainability certificates ENERGY STAR
Weight & dimensions
Package width 19.8" (502.9 mm)
Package depth 23.5" (596.9 mm)
Package height 9.6" (243.8 mm)
Weight 28 lbs (12.7 kg)
Width 17.2" (437.9 mm)
Package weight 44.1 lbs (20 kg)
Height 3.46" (87.9 mm)
Depth 15.6" (397 mm)
Packaging data
Manual Yes
Cables included Input power cable, Output power cable, USB cable
Package width 19.8" (502.9 mm)
Package depth 23.5" (596.9 mm)
Package height 9.6" (243.8 mm)
Package weight 44.1 lbs (20 kg)
Logistics data
Country of origin China
Products per master (outer) case 1 pc(s)
Master (outer) case width 19.8" (502.9 mm)
Master (outer) case length 23.5" (596.9 mm)
Master (outer) case height 9.6" (243.8 mm)
Master (outer) case gross weight 44.1 lbs (20 kg)