{"product_id":"lenovo-s4520-25-192-tb-serial-ata-iii-3d-tlc-nand-4xb7a17103","title":"Lenovo S4520 2.5\" 1.92 TB Serial ATA III 3D TLC NAND","description":"\u003cstyle\u003etable.generic tr th {background: #eee;}\u003c\/style\u003eThinkSystem 2.5\" S4520 1.92TB Read Intensive SATA 6Gb HS SSD\u003ch2\u003eDescription\u003c\/h2\u003eThe ThinkSystem S4520 Read Intensive SATA SSDs are advanced 6Gb SATA solid-state drives that use 144-layer Intel 3D NAND TLC Flash Memory technology to provide an affordable solution with industry leading performance.\u003cbr\u003e\u003cbr\u003eThis product guide provides essential presales information to understand the S4520 SSDs, their key features and specifications, components and options, and configuration guidelines. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about S4520 SSDs and consider their use in IT solutions.\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"generic\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eHard drive\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD capacity\u003c\/td\u003e\n\u003ctd\u003e1.92 TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory type\u003c\/td\u003e\n\u003ctd\u003e3D TLC NAND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eData transmission\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRandom write (4KB)\u003c\/td\u003e\n\u003ctd\u003e38000 IOPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRandom read (4KB)\u003c\/td\u003e\n\u003ctd\u003e91000 IOPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndurance rating\u003c\/td\u003e\n\u003ctd\u003e8.8 PB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData transfer rate\u003c\/td\u003e\n\u003ctd\u003e6 Gbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eEndurance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUncorrectable Bit Error Rate (UBER)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 per 10^17 bits read\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMean time between failures (MTBF)\u003c\/td\u003e\n\u003ctd\u003e2000000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eCertificates\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eFCC Title 47, Part 15B, Class B\nEN-55035:2017\nEN-55022:2006\nEN-55032:2012\nLow Voltage Directive (LVD) 2014\/35\/EU\nEMC Directive 2014\/30\/EU\nRoHS Directive 2011\/65\/EU\nWEEE Directive 2012\/19\/EU\nUL 60950-1, 2nd Edition, 2014-10-14\nCSA C22.2 No. 60950-1-07, 2nd Edition, 2014-010\nUL\/CSA 62368-1, 2nd Edition\nAS\/NZ CISPR 32:2015\nAS\/NZ CISPR 22:2009 +A1:2010\nTaiwan BSMI EMC standard CNS 13438\nKorea KCC Article 11.1\nMorocco Decree # 2574-14 (EMC)\nCanada ICES-003\nJapan VCCI\nChina EFUP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePerformance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eSerial ATA III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent for\u003c\/td\u003e\n\u003ctd\u003eServer\/workstation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD capacity\u003c\/td\u003e\n\u003ctd\u003e1.92 TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory type\u003c\/td\u003e\n\u003ctd\u003e3D TLC NAND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUncorrectable Bit Error Rate (UBER)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 per 10^17 bits read\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRandom write (4KB)\u003c\/td\u003e\n\u003ctd\u003e38000 IOPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRandom read (4KB)\u003c\/td\u003e\n\u003ctd\u003e91000 IOPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMean time between failures (MTBF)\u003c\/td\u003e\n\u003ctd\u003e2000000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData transfer rate\u003c\/td\u003e\n\u003ctd\u003e6 Gbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eDesign\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent for\u003c\/td\u003e\n\u003ctd\u003eServer\/workstation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eFCC Title 47, Part 15B, Class B\nEN-55035:2017\nEN-55022:2006\nEN-55032:2012\nLow Voltage Directive (LVD) 2014\/35\/EU\nEMC Directive 2014\/30\/EU\nRoHS Directive 2011\/65\/EU\nWEEE Directive 2012\/19\/EU\nUL 60950-1, 2nd Edition, 2014-10-14\nCSA C22.2 No. 60950-1-07, 2nd Edition, 2014-010\nUL\/CSA 62368-1, 2nd Edition\nAS\/NZ CISPR 32:2015\nAS\/NZ CISPR 22:2009 +A1:2010\nTaiwan BSMI EMC standard CNS 13438\nKorea KCC Article 11.1\nMorocco Decree # 2574-14 (EMC)\nCanada ICES-003\nJapan VCCI\nChina EFUP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD form factor\u003c\/td\u003e\n\u003ctd\u003e2.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eFeatures\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eSerial ATA III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent for\u003c\/td\u003e\n\u003ctd\u003eServer\/workstation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD capacity\u003c\/td\u003e\n\u003ctd\u003e1.92 TB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory type\u003c\/td\u003e\n\u003ctd\u003e3D TLC NAND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUncorrectable Bit Error Rate (UBER)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 per 10^17 bits read\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRandom write (4KB)\u003c\/td\u003e\n\u003ctd\u003e38000 IOPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRandom read (4KB)\u003c\/td\u003e\n\u003ctd\u003e91000 IOPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMean time between failures (MTBF)\u003c\/td\u003e\n\u003ctd\u003e2000000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData transfer rate\u003c\/td\u003e\n\u003ctd\u003e6 Gbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eFCC Title 47, Part 15B, Class B\nEN-55035:2017\nEN-55022:2006\nEN-55032:2012\nLow Voltage Directive (LVD) 2014\/35\/EU\nEMC Directive 2014\/30\/EU\nRoHS Directive 2011\/65\/EU\nWEEE Directive 2012\/19\/EU\nUL 60950-1, 2nd Edition, 2014-10-14\nCSA C22.2 No. 60950-1-07, 2nd Edition, 2014-010\nUL\/CSA 62368-1, 2nd Edition\nAS\/NZ CISPR 32:2015\nAS\/NZ CISPR 22:2009 +A1:2010\nTaiwan BSMI EMC standard CNS 13438\nKorea KCC Article 11.1\nMorocco Decree # 2574-14 (EMC)\nCanada ICES-003\nJapan VCCI\nChina EFUP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD form factor\u003c\/td\u003e\n\u003ctd\u003e2.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRandom latency - read (up to)\u003c\/td\u003e\n\u003ctd\u003e104 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRandom latency - write (up to)\u003c\/td\u003e\n\u003ctd\u003e54 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSequential latency - read (up to)\u003c\/td\u003e\n\u003ctd\u003e37 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSequential latency - write (up to)\u003c\/td\u003e\n\u003ctd\u003e38 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive writes per day (DWPD)\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption (write)\u003c\/td\u003e\n\u003ctd\u003e3.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eOperational conditions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e0 - 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e5 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating shock\u003c\/td\u003e\n\u003ctd\u003e1000 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating shock\u003c\/td\u003e\n\u003ctd\u003e1000 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating vibration\u003c\/td\u003e\n\u003ctd\u003e2.17 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating vibration\u003c\/td\u003e\n\u003ctd\u003e3.13 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eTechnical details\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eSerial ATA III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e0 - 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e5 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating shock\u003c\/td\u003e\n\u003ctd\u003e1000 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating shock\u003c\/td\u003e\n\u003ctd\u003e1000 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating vibration\u003c\/td\u003e\n\u003ctd\u003e2.17 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating vibration\u003c\/td\u003e\n\u003ctd\u003e3.13 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSSD form factor\u003c\/td\u003e\n\u003ctd\u003e2.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eWeight \u0026amp; dimensions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e6.85\" (174 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e15.3 oz (434 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e2.48\" (63 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e5.24\" (133 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eOther features\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUncorrectable Bit Error Rate (UBER)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 per 10^17 bits read\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndurance rating\u003c\/td\u003e\n\u003ctd\u003e8.8 PB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Lenovo","offers":[{"title":"Default Title","offer_id":47892778057981,"sku":"4XB7A17103","price":5503.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/0860\/6205\/files\/NhRnwimM102Uxaedke3g0w.c-m.jpg?v=1784982704","url":"https:\/\/buyitsolutions.com\/products\/lenovo-s4520-25-192-tb-serial-ata-iii-3d-tlc-nand-4xb7a17103","provider":"Buy IT Solutions","version":"1.0","type":"link"}