{"product_id":"apc-srt3000xlt-uninterruptible-power-supply-ups-double-conversion-online-3-kva-2700-w-3-ac-outlets","title":"APC SRT3000XLT uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA 2700 W 3 AC outlet(s)","description":"\u003cstyle\u003etable.generic tr th {background: #eee;}\u003c\/style\u003e3000VA, 2700W, 208V, 50\/60Hz, LCD, IP20, 31.3kg, Black\u003ch2\u003eDescription\u003c\/h2\u003eAPC Smart-UPS SRT 3000VA 208V\u003cbr\u003e\u003cbr\u003eHigh density, double-conversion on-line power protection with scalable runtime\u003cbr\u003e\u003cbr\u003eIncludes : CD with software , Documentation CD , Installation guide , Removable support feet , USB cable , Warranty card\u003cbr\u003e\u003cbr\u003eBattery failure notification\u003cbr\u003eProvides early-warning fault analysis on batteries enabling timely preventive maintenance\u003cbr\u003eECO Mode\u003cbr\u003eOperating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection\u003cbr\u003eGreen mode\u003cbr\u003ePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.\u003cbr\u003eLCD graphics display\u003cbr\u003eText and mimic diagrams that display modes of operation, system parameters and alarms.\u003cbr\u003eRack\/Tower convertible\u003cbr\u003eProtects the initial investment in the UPS when migrating from tower to rack-mount environment.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSmart-UPS On-Line Features \u0026amp; Benefits\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAvailability\u003c\/b\u003e\u003cbr\u003eHot-swappable batteries\u003cbr\u003eEnsures clean, uninterrupted power to protected equipment while batteries are being replaced\u003cbr\u003eAutomatic restart of loads after UPS shutdown\u003cbr\u003eAutomatically starts up the connected equipment upon the return of utility power.\u003cbr\u003eTemperature-compensated battery charging\u003cbr\u003eProlongs battery life by regulating the charge voltage according to battery temperature.\u003cbr\u003eIntelligent battery management\u003cbr\u003eMaximizes battery performance, life, and reliability through intelligent, precision charging.\u003cbr\u003eAutomatic internal bypass\u003cbr\u003eSupplies utility power to the connected loads in the event of a UPS power overload or fault.\u003cbr\u003eScalable runtime\u003cbr\u003eAllows additional run time to be quickly added as needed.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eManageability\u003c\/b\u003e\u003cbr\u003eNetwork manageable\u003cbr\u003eProvides remote power management of the UPS over the network.\u003cbr\u003eInfraStruXure Manager Compatible\u003cbr\u003eEnables centralized management via the APC InfraStruXure Manager.\u003cbr\u003eSmartSlot\u003cbr\u003eCustomize UPS capabilities with management cards.\u003cbr\u003eLED status indicators\u003cbr\u003eQuickly understand unit and power status with visual indicators.\u003cbr\u003eSerial connectivity\u003cbr\u003eProvides management of the UPS via a serial port.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eProtection\u003c\/b\u003e\u003cbr\u003eGenerator compatible\u003cbr\u003eEnsures clean, uninterrupted power to protected equipment when generator power is used.\u003cbr\u003eSafety-agency approved\u003cbr\u003eEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.\u003cbr\u003eResettable circuit breaker\u003cbr\u003eEasy recovery from overloads; no need to replace a fuse.\u003cbr\u003ePower conditioning\u003cbr\u003eProtects connected loads from surges, spikes, lightning, and other power disturbances.\u003cbr\u003eCold-start capable\u003cbr\u003eProvides temporary battery power when the utility power is out.\u003cbr\u003eInput power factor correction\u003cbr\u003eMinimizes installation costs by enabling the use of smaller generators and cabling.\u003cbr\u003eFrequency and voltage regulation\u003cbr\u003eGives higher application availability by correcting poor frequency and voltage conditions without using the battery.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eMarketing Features\u003c\/b\u003e\u003cbr\u003eSave time with easy and convenient remote accessibility.\u003cbr\u003eNetwork manageable via serial, USB or optional Ethernet. Includes Powerchute® Network Shutdown Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.\u003cbr\u003eLow operating and maintenance costs with proven reliability and intelligent battery management.\u003cbr\u003eIntelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.\u003cbr\u003eAvoids costly power problems by keeping your IT equipment and data protected and available.\u003cbr\u003eNetwork grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.\u003cbr\u003ePeace of mind that comes with full equipment compatibility and reliability of a leader\u003cbr\u003eProvides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAdaptability\u003c\/b\u003e\u003cbr\u003ePlug-and-Play external batteries\u003cbr\u003eEnsures clean, uninterrupted power to the loads when adding extra runtime to the UPS.\u003cbr\u003eRack\/Tower convertible\u003cbr\u003eProtects the initial investment in the UPS when migrating from tower to rack-mount environment.\u003cbr\u003eFlash upgradeable firmware\u003cbr\u003eInstall maintenance releases of firmware remotely using FTP.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eServiceability\u003c\/b\u003e\u003cbr\u003ePredicitive failure notification\u003cbr\u003eProvides early-warning fault analysis ensuring proactive component replacement.\u003cbr\u003eDisconnected battery notification\u003cbr\u003eWarns when a battery is not available to provide backup power.\u003cbr\u003eUser-replaceable batteries\u003cbr\u003eIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)\u003cbr\u003eAutomatic self-test\u003cbr\u003ePeriodic battery self-test ensures early detection of a battery that needs to be replaced.\u003cbr\u003eAudible alarms\u003cbr\u003eProvides notification of changing utility power and UPS power conditions\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"generic\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power\u003c\/td\u003e\n\u003ctd\u003e2700 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput operation voltage (min)\u003c\/td\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e275 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput operation voltage (min)\u003c\/td\u003e\n\u003ctd\u003e208 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge energy rating\u003c\/td\u003e\n\u003ctd\u003e340 J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e91%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest factor\u003c\/td\u003e\n\u003ctd\u003e3:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power capacity\u003c\/td\u003e\n\u003ctd\u003e3 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePerformance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm modes\u003c\/td\u003e\n\u003ctd\u003eBattery replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPS topology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion (Online)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003eSine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise level\u003c\/td\u003e\n\u003ctd\u003e55 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm(s)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eFeatures\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm modes\u003c\/td\u003e\n\u003ctd\u003eBattery replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPS topology\u003c\/td\u003e\n\u003ctd\u003eDouble-conversion (Online)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003eSine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power\u003c\/td\u003e\n\u003ctd\u003e2700 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput operation voltage (min)\u003c\/td\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e275 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput operation voltage (min)\u003c\/td\u003e\n\u003ctd\u003e208 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput operation voltage (max)\u003c\/td\u003e\n\u003ctd\u003e240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge energy rating\u003c\/td\u003e\n\u003ctd\u003e340 J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e91%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency Power Off (EPO)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise level\u003c\/td\u003e\n\u003ctd\u003e55 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest factor\u003c\/td\u003e\n\u003ctd\u003e3:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible alarm(s)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power capacity\u003c\/td\u003e\n\u003ctd\u003e3 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage type\u003c\/td\u003e\n\u003ctd\u003eBox\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePorts \u0026amp; interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC outlets quantity\u003c\/td\u003e\n\u003ctd\u003e3 AC outlet(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC outlet types\u003c\/td\u003e\n\u003ctd\u003eNEMA L6-20R, NEMA L6-30P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower plug\u003c\/td\u003e\n\u003ctd\u003eNEMA L6-20P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB 2.0 ports quantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial ports quantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet LAN (RJ-45) ports\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eBattery\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of batteries supported\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e96 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery technology\u003c\/td\u003e\n\u003ctd\u003eSealed Lead Acid (VRLA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery recharge time\u003c\/td\u003e\n\u003ctd\u003e3 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical backup time at half load\u003c\/td\u003e\n\u003ctd\u003e8.3 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical backup time at full load\u003c\/td\u003e\n\u003ctd\u003e2.3 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eDesign\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternational Protection (IP) code\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No.107.3-05, FCC Part 15 Class A, UL 1778\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eOperational conditions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e0 - 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-15 - 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e0 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e0 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eTechnical details\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSustainability certificates\u003c\/td\u003e\n\u003ctd\u003eENERGY STAR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eCertificates\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No.107.3-05, FCC Part 15 Class A, UL 1778\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eSustainability\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSustainability certificates\u003c\/td\u003e\n\u003ctd\u003eENERGY STAR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eWeight \u0026amp; dimensions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage type\u003c\/td\u003e\n\u003ctd\u003eBox\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage width\u003c\/td\u003e\n\u003ctd\u003e23.6\" (599 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage depth\u003c\/td\u003e\n\u003ctd\u003e34.3\" (871 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage height\u003c\/td\u003e\n\u003ctd\u003e9.69\" (246 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e69 lbs (31.3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e3.35\" (85 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage weight\u003c\/td\u003e\n\u003ctd\u003e80.9 lbs (36.7 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e17\" (432 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e25\" (635 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePackaging data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage type\u003c\/td\u003e\n\u003ctd\u003eBox\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage width\u003c\/td\u003e\n\u003ctd\u003e23.6\" (599 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage depth\u003c\/td\u003e\n\u003ctd\u003e34.3\" (871 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage height\u003c\/td\u003e\n\u003ctd\u003e9.69\" (246 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage weight\u003c\/td\u003e\n\u003ctd\u003e80.9 lbs (36.7 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eLogistics data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProducts per pallet\u003c\/td\u003e\n\u003ctd\u003e6 pc(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"APC","offers":[{"title":"Default Title","offer_id":47280891068669,"sku":"SRT3000XLT","price":4008.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/0860\/6205\/files\/lWgInbaHNkyen7dcIUNNPA.c-m.jpg?v=1774551573","url":"https:\/\/buyitsolutions.com\/products\/apc-srt3000xlt-uninterruptible-power-supply-ups-double-conversion-online-3-kva-2700-w-3-ac-outlets","provider":"Buy IT Solutions","version":"1.0","type":"link"}